Measure Deviation

images/download/attachments/137619694/CreateLabel.svg

This command creates new labels on object with intensities or deviations. Such labels are generally used after inspection to prepare an inspection report.

To create a new label, launch the command and click in the 3D scene on an object.

  1. Set both tolerances (Tol+/Tol-).

    These parameters are only suitable for compared object when both objects (colored measured + reference

    or colored reference + measured) are still in the current project with their initial names.

    Note also the label size must be long to read all details. You can set this parameters thanks to Label settings.

  2. Choose the ID Number of the next label.

  3. Optionally, write a Comment for the next label.

  4. Click onto the object to add the label.

  5. Continue clicking to add another ones. Click OK to validate and exit or Cancel to exit.

Information about labels

images/download/attachments/137619694/CreateLabel.png

The number of "+" or "-" sign depends on position of measurement inside the tolerance:

  • + The distance between reference and measurement is between 0 and 25% of the high tolerance.

  • ++ The distance between reference and measurement is between 25 and 50% of the high tolerance.

  • +++ The distance between reference and measurement is between 50 and 75% of the high tolerance.

  • ++++ The distance between reference and measurement is between 75 and 100% of the high tolerance.

  • ++++! The distance between reference and measurement is out of the high tolerance. In this case the character string is displayed with a red color.

  • - The distance between reference and measurement is between 0 and 25% of the low tolerance.

  • -- The distance between reference and measurement is between 25 and 50% of the low tolerance.

  • --- The distance between reference and measurement is between 50 and 75% of the low tolerance.

  • ---- The distance between reference and measurement is between 75 and 100% of the low tolerance.

  • ----! The distance between reference and measurement is out of the low tolerance. In this case the character string is displayed with a blue-cyan color.

  • images/download/thumbnails/137619694/image2017-2-16_17_46_2.png The distance is very close to 0.