Scalar Range

images/download/attachments/191398986/CloudSeparateWithInspectionValues.svg

This command filters points inside cloud(s) according to a range of inspection, density or timestamp values.

Requirements

Select at least one cloud containing inspection, density or timestamp values and launch the command.


Define the output points you want:

  • Inside range points.

  • Outside range points.

Notes

  • For the initialization, if the cloud does not contain pegs, the lower slider is defined to 10% of the range, and the upper slider is defined to 90%. Otherwise, the lower slider is defined at the first peg value, and the upper slider is defined at the last peg value. Adjust the Scalar values range.

  • If multiple clouds are selected, the gradient must be identical to launch the command.

  • The gradient used will depend on the reprensentation of the input(s)